Rev Sci Instrum ; 94(1): 013101, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725595

RESUMO

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX's) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3-11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 µm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics' OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

2.
Curr Oncol ; 25(Suppl 1): S115-S124, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29910654

RESUMO

Although screening mammography has delivered many benefits since its introduction in Canada in 1988, questions about perceived harms warrant an up-to-date review. To help oncologists and physicians provide optimal patient recommendations, the literature was reviewed to find the latest guidelines for screening mammography, including benefits and perceived harms of overdiagnosis, false positives, false negatives, and technologic advances. For women 40-74 years of age who actually participate in screening every 1-2 years, breast cancer mortality is reduced by 40%. With appropriate corrections, overdiagnosis accounts for 10% or fewer breast cancers. False positives occur in about 10% of screened women, 80% of which are resolved with additional imaging, and 10%, with breast biopsy. An important limitation of screening is the false negatives (15%-20%). The technologic advances of digital breast tomosynthesis, breast ultrasonography, and magnetic resonance imaging counter the false negatives of screening mammography, particularly in women with dense breast tissue.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer , Biópsia , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Detecção Precoce de Câncer/história , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/tendências , Reações Falso-Positivas , Feminino , História do Século XXI , Humanos , Imageamento por Ressonância Magnética , Mamografia , Programas de Rastreamento/história , Programas de Rastreamento/métodos , Programas de Rastreamento/tendências , Oncologia/história , Oncologia/métodos , Oncologia/tendências , Ultrassonografia Mamária
3.
Artigo em Inglês | MEDLINE | ID: mdl-31093030

RESUMO

The properties of hot, dense plasmas generated by the irradiation of GaAs targets by the Titan laser at Lawrence Livermore National Laboratory were determined by the analysis of high resolution K shell spectra in the 9 keV to 11 keV range. The laser parameters, such as relatively long pulse duration and large focal spot, were chosen to produce a steady-state plasma with minimal edge gradients, and the time-integrated spectra were compared to non-LTE steady state spectrum simulations using the FLYCHK and NOMAD codes. The bulk plasma streaming velocity was measured from the energy shifts of the Ga He-like transitions and Li-like dielectronic satellites. The electron density and the electron energy distribution, both the thermal and the hot non-thermal components, were determined from the spectral line ratios. After accounting for the spectral line broadening contributions, the plasma turbulent motion was measured from the residual line widths. The ionization balance was determined from the ratios of the He-like through F-like spectral features. The detailed comparison of the experimental Ga spectrum and the spectrum simulated by the FLYCHK code indicates two significant discrepancies, the transition energy of a Li-like dielectronic satellite (designated t) and the calculated intensity of a He-like line (x), that should lead to improvements in the kinetics codes used to simulate the X-ray spectra from highly-charged ions.

4.
Eur J Cancer Care (Engl) ; 27(2): e12727, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28639355

RESUMO

Diagnostic assessment programmes (DAPs) coordinate multidisciplinary teamwork (MDT), and improve wait times and patient satisfaction. No research has established optimal DAP design. This study explored how DAP characteristics influence service delivery. A mixed methods case study of four breast cancer DAPs was conducted including qualitative interviews with health-care providers and retrospective chart review. Data were integrated using multiple approaches. Twenty-three providers were interviewed; 411 medical records were reviewed. The number of visits and wait times from referral to diagnosis and consultation were lowest at a one-stop model. DAP characteristics (rural-remote region, human resources, referral volume, organisation of services, adherence to service delivery targets and one-stop model) may influence service delivery (number of visits, wait times). MDT, influenced by other DAP characteristics (co-location of staff, patient navigators, team functioning), may also influence service delivery. While the one-stop model may be ideal, all sites experienced similar and unique challenges. Further research is needed to understand how to optimise the organisation and delivery of DAP services. Measures reflecting individual, team and patient-reported outcomes should be used to assess the effectiveness and impact of DAPs in addition to more traditional measures such as wait times.


Assuntos
Neoplasias da Mama/diagnóstico , Atenção à Saúde , Equipe de Assistência ao Paciente/organização & administração , Adulto , Idoso , Atenção à Saúde/organização & administração , Atenção à Saúde/normas , Feminino , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente , Avaliação de Programas e Projetos de Saúde , Pesquisa Qualitativa , Estudos Retrospectivos , Adulto Jovem
5.
Phys Rev Lett ; 119(18): 182501, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219591

RESUMO

We report the measurement of the beam-vector and tensor asymmetries A_{ed}^{V} and A_{d}^{T} in quasielastic (e[over →],e^{'}p) electrodisintegration of the deuteron at the MIT-Bates Linear Accelerator Center up to missing momentum of 500 MeV/c. Data were collected simultaneously over a momentum transfer range 0.1

6.
Clin Radiol ; 72(9): 796.e9-796.e17, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28495011

RESUMO

AIM: To analyse and compare the computed tomography (CT) features of benign and malignant types of histopathologically proven cases of solitary fibrous tumours of pleura (SFTP). MATERIALS AND METHODS: Retrospective analysis of preoperative CT images of 28 cases of histopathologically proven and classified SFTP from three participating institutions was performed. Patient demographics and lesion characteristics including size, borders, presence of a pedicle, extension into the fissure, attenuation, enhancement, pleural effusion, and calcifications were recorded and correlated with the final histopathological diagnosis. Type and results of preoperative biopsy were also recorded. Follow-up imaging and the clinical charts were reviewed to identify recurrence. RESULTS: Out of 28 cases (15 women and 13 men), 18 were proven to be benign and 10 were malignant. The mean age of patients was 58.1±15.9 and 66.5±11.8 years (p=0.1564) for benign and malignant tumours, respectively. The median (interquartile range) diameter was 6.05 (3.2-10.9) cm for benign and 15.7 (7.1-17.5) cm for malignant type tumours (p=0.0291). Tumours had lobulate borders in 28% (5/18) of benign cases and in 80% (8/10) of malignant cases (p=0.0163). Extension into adjacent fissure was seen in 22% (4/18) of benign lesions and 40% (4/10) of malignant lesions (p=0.40). A pedicle was present in 17% (3/18) of benign and 10% (1/10) of malignant lesions (p=1). Heterogeneous attenuation was present in 61% (11/18) of benign and 90% (9/10) of malignant lesions (p=0.19). Calcification was present in 17% (3/18) of benign tumours and in 70% (7/10) of malignant tumours (p=0.0113). Pleural effusion was present in 6% (1/18) of benign and 40% (4/10) of malignant lesions (p=0.04). Only 1/13 preoperative fine-needle aspirates yielded diagnosis of SFTP. Preoperative diagnosis of SFTP was made in all cases (11/11) with core biopsies. At follow-up (1-10 years, mean 3 years), local recurrence occurred in 3/6 (50%) patients with malignant SFTP and in none of the 10 patients with benign SFTP. CONCLUSION: No definite imaging feature to differentiate benign from malignant SFTP was found. Large size, lobulate borders, presence of calcification, and ipsilateral pleural effusion were the only CT features predictive of malignancy. In suspected cases, core biopsies should be performed rather than fine-needle aspiration.


Assuntos
Tumor Fibroso Solitário Pleural/diagnóstico por imagem , Tumor Fibroso Solitário Pleural/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Rev Sci Instrum ; 87(11): 11E305, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910617

RESUMO

A Cauchois transmission-crystal spectrometer has been developed with high crystal resolving power in the 6 keV-15 keV energy range and sufficient sensitivity to record single-shot spectra from the Lawrence Livermore National Laboratory (LLNL) Titan laser and other comparable or more energetic lasers. The spectrometer capabilities were tested by recording the W L transitions from a laboratory source and the extended x-ray absorption fine structure (EXAFS) spectrum through a Cu foil.

8.
Artigo em Inglês | MEDLINE | ID: mdl-31093029

RESUMO

Experiments were performed at the LLNL Titan laser to measure the propagation direction of the energetic electrons that were generated during the interaction of the polarized laser beam with solid targets in the case of normal incidence. The energetic electrons propagated through vacuum to spectator metal wires in the polarization direction and in the perpendicular direction, and the K shell spectra from the different wire materials were recorded as functions of the distance from the laser focal spot. It was found that the fluence of the energetic electrons driven into the spectator wires in the polarization direction compared to the perpendicular direction was larger and increased with the distance from the focal spot. This indicates that energetic electrons are preferentially driven in the direction of the intense oscillating electric field of the incident laser beam in agreement with the multiphoton inverse Bremsstrahlung absorption process.

9.
Rev Sci Instrum ; 85(11): 11D618, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430194

RESUMO

A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10-60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 µm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10-60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

11.
Br J Radiol ; 87(1039): 20140182, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24846442

RESUMO

OBJECTIVE: To determine the rate of underestimation of malignancy in patients with biopsy-proven stromal fibrosis. METHODS: Following institutional review board approval, we retrospectively reviewed the charts of patients with biopsy-proven stromal fibrosis who underwent percutaneous breast biopsy in the 5-year period between 1 January 2005 and 31 December 2009. The medical records and the histopathology in patients who underwent repeat biopsy and/or surgical excision at the site of stromal fibrosis within 2 years were reviewed. Interval stability for up to 2 years was documented in patients who did not undergo additional biopsy or surgical excision. An upgrade was defined as any patient with biopsy-proven stromal fibrosis or fibroadenoma with evidence of malignancy at the site of biopsy within 2 years. RESULTS: 365 cases of stromal fibrosis were identified, of which 25 (7%) were upgraded to in situ or invasive malignancy on repeat biopsy or surgical excision. 7 were upgraded to ductal carcinoma in situ and 18 were upgraded to invasive cancer. Of the upgraded cases, 8 out of 24 (32%) were considered concordant with a benign diagnosis. The false-negative rate, that is, cases of stromal fibrosis concordant with benignity, but with subsequent upgrade, comprised 2% of all cases. CONCLUSION: In biopsy-proven cases of stromal fibrosis, there is a 7% upgrade to malignancy. We recommend that all instances of stromal fibrosis with radiology-pathology discordance undergo repeat biopsy or surgical excision. Cases that demonstrate radiology-pathology concordance can be safely categorized as a Breast Imaging Reporting and Data System 3 (BI-RADS® 3) lesion with a 6-month follow-up, owing to a false-negative rate for missed cancer of 2%. ADVANCES IN KNOWLEDGE: We now recommend that concordant cases of stromal fibrosis be categorized as BI-RADS 3 with a short-term follow-up, as this results in a missed cancer rate of 2%.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Adulto , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Carcinoma Lobular/patologia , Feminino , Fibroadenoma/patologia , Fibrose , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
Rev Sci Instrum ; 83(10): 10E110, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126932

RESUMO

Close to an x-ray filter's K-edge the transmission depends strongly on the photon energy. For a few atom pairs, the K-edge of one is only a few tens of eV higher than a K-line energy of another, so that a small change in the line's energy becomes a measurable change in intensity behind such a matching filter. Lutetium's K-edge is ≃27 eV above iridium's Kα(2) line, ≃63.287 keV for cold Ir. A Lu filter reduces this line's intensity by ≃10 % when it is emitted by a plasma, indicating an ionization shift Δε≃10±1 eV.

13.
Rev Sci Instrum ; 83(10): 10E113, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126935

RESUMO

We investigated various diagnostic techniques to measure the 511 keV annihilation radiations. These include step-wedge filters, transmission crystal spectroscopy, single-hit CCD detectors, and streaked scintillating detection. While none of the diagnostics recorded conclusive results, the step-wedge filter that is sensitive to the energy range between 100 keV and 700 keV shows a signal around 500 keV that is clearly departing from a pure Bremsstrahlung spectrum and that we ascribe to annihilation radiation.

14.
Br J Radiol ; 85(1015): 848-64, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22745203

RESUMO

Pulmonary lymphoproliferative disorders (LPD) are characterised by abnormal proliferation of indigenous cell lines or infiltration of lung parenchyma by lymphoid cells. They encompass a wide spectrum of focal or diffuse abnormalities, which may be classified as reactive or neoplastic on the basis of cellular morphology and clonality. The spectrum of reactive disorders results primarily from antigenic stimulation of bronchial mucosa-associated lymphoid tissue (MALT) and comprises three main entities: follicular bronchiolitis, lymphoid interstitial pneumonia and (more rarely) nodular lymphoid hyperplasia. Primary parenchymal neoplasms are most commonly extranodal marginal zone lymphomas of MALT origin (MALT lymphomas), followed by diffuse large B-cell lymphomas (DLBCLs) and lymphomatoid granulomatosis (LYG). Secondary lymphomatous parenchymal neoplasms (both Hodgkin and non-Hodgkin lymphomas) are far more prevalent than primary neoplasms. Acquired immune deficiency syndrome (AIDS)-related lymphoma (ARL) and post-transplantation lymphoproliferative disorder (PTLD) may also primarily affect the lung parenchyma. Modern advances in treatments for AIDS and transplant medicine are associated with an increase in the incidence of LPD and have heightened the need to understand the range of imaging appearance of these diseases. The multidetector CT (MDCT) findings of LPD are heterogeneous, thereby reflecting the wide spectrum of clinical manifestations of these entities. Understanding the spectrum of LPD and the various imaging manifestations is crucial because the radiologist is often the first one to suggest the diagnosis and has a pivotal role in differentiating these diseases. The current concepts of LPD are discussed together with a demonstration of the breadth of MDCT patterns within this disease spectrum.


Assuntos
Pneumopatias/diagnóstico por imagem , Transtornos Linfoproliferativos/classificação , Transtornos Linfoproliferativos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Adolescente , Adulto , Biópsia por Agulha , Transformação Celular Neoplásica/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imuno-Histoquímica , Pneumopatias/classificação , Pneumopatias/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Linfoma de Células B/diagnóstico por imagem , Linfoma de Células B/patologia , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Linfoma de Zona Marginal Tipo Células B/patologia , Granulomatose Linfomatoide/diagnóstico por imagem , Granulomatose Linfomatoide/patologia , Transtornos Linfoproliferativos/patologia , Masculino , Pessoa de Meia-Idade , Pseudolinfoma/diagnóstico por imagem , Pseudolinfoma/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
15.
Rev Sci Instrum ; 83(4): 043104, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559512

RESUMO

In the pursuit of novel, laser-produced x-ray sources for medical imaging applications, appropriate instrumental diagnostics need to be developed concurrently. A type of transmission crystal spectroscopy has previously been demonstrated as a survey tool for sources produced by high-power and high-energy lasers. The present work demonstrates the extension of this method into the study of medium-intensity laser driven hard x-ray sources with a design that preserves resolving power while maintaining high sensitivity. Specifically, spectroscopic measurements of characteristic Kα and Kß emissions were studied from Mo targets irradiated by a 100 fs, 200 mJ, Ti: sapphire laser with intensity of 10(17) W/cm(2) to 10(18) W∕cm(2) per shot. Using a transmission curved crystal spectrometer and off-Rowland circle imaging, resolving powers (E/ΔE) of around 300 for Mo Kα(2) at 17.37 keV were obtained with an end-to-end spectrometer efficiency of (1.13 ± 0.10) × 10(-5). This sensitivity is sufficient for registering x-ray lines with high signal to background from targets following irradiation by a single laser pulse, demonstrating the utility of this method in the study of the development of medium-intensity laser driven x-ray sources.

16.
Clin Radiol ; 66(7): 589-96, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21530954

RESUMO

Systemic arterial air embolism is a rarely encountered but much feared complication of percutaneous lung biopsy. We present a comprehensive review of iatrogenic air embolism post-lung biopsy, a complication that is often suboptimally managed. This review was inspired by our own institutional experience and we use this to demonstrate that excellent outcomes from this complication can be seen with prompt treatment using hyperbaric oxygen chamber therapy, after initial patient stabilization has been achieved. Pathophysiology, clinical features, and risk factors are reviewed and misconceptions regards venous versus arterial air embolism are examined. An algorithm is provided for radiologists to ensure suspected patients are appropriately managed with more favourable outcomes.


Assuntos
Biópsia por Agulha/efeitos adversos , Embolia Aérea/etiologia , Pulmão/patologia , Artérias , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/terapia , Humanos , Oxigenoterapia Hiperbárica/métodos , Tomografia Computadorizada por Raios X/métodos
17.
Phys Rev Lett ; 107(25): 252501, 2011 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-22243068

RESUMO

We report a precision measurement of the deuteron tensor analyzing powers T(20) and T(21) at the MIT-Bates Linear Accelerator Center. Data were collected simultaneously over a momentum transfer range Q=2.15-4.50 fm(-1) with the Bates Large Acceptance Spectrometer Toroid using a highly polarized deuterium internal gas target. The data are in excellent agreement with calculations in a framework of effective field theory. The deuteron charge monopole and quadrupole form factors G(C) and G(Q) were separated with improved precision, and the location of the first node of G(C) was confirmed at Q=4.19±0.05 fm(-1). The new data provide a strong constraint on theoretical models in a momentum transfer range covering the minimum of T(20) and the first node of G(C).

18.
Rev Sci Instrum ; 81(10): 10E302, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034001

RESUMO

The plasma-filled rod-pinch diode (PFRP) is an intense source of x-rays ideal for radiography of dense objects. In the PRFP megavoltage electrons from a pulsed discharge concentrate at the pointed end of a 1 mm diameter tapered tungsten rod. Ionization of this plasma might increase the energy of tungsten's Kα(1) fluorescence line, at 59.3182 keV, enough for the difference to be observed by a high-resolution Cauchois transmission crystal spectrograph. When the PFRP's intense hard bremsstrahlung is suppressed by the proper shielding, such an instrument gives excellent fluorescence spectra, albeit with as yet insufficient resolution to see any effect of tungsten's ionization. Higher resolution is possible with various straightforward upgrades that are feasible thanks to the radiation's high intensity.

19.
Rev Sci Instrum ; 81(10): 10E301, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034000

RESUMO

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

20.
Rev Sci Instrum ; 81(10): 10E311, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034010

RESUMO

The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.